ipq806x: 5:15: drop upstream patch
[openwrt/staging/chunkeey.git] / target / linux / ipq806x / patches-5.15 / 105-10-drivers-thermal-tsens-Fix-wrong-slope-on-msm-8960.patch
diff --git a/target/linux/ipq806x/patches-5.15/105-10-drivers-thermal-tsens-Fix-wrong-slope-on-msm-8960.patch b/target/linux/ipq806x/patches-5.15/105-10-drivers-thermal-tsens-Fix-wrong-slope-on-msm-8960.patch
deleted file mode 100644 (file)
index 6cdc0b2..0000000
+++ /dev/null
@@ -1,32 +0,0 @@
-From 68e720ed73c8f038c8c500e4c49c1e65a993a448 Mon Sep 17 00:00:00 2001
-From: Ansuel Smith <ansuelsmth@gmail.com>
-Date: Tue, 6 Apr 2021 04:45:31 +0200
-Subject: [PATCH 10/10] drivers: thermal: tsens: Fix wrong slope on msm-8960
-
-Some user using some stats with the old legacy implementation and the
-new implementation using the compute_intercept_slope reported an offset
-of 3C. Fix the slope table to reflect the original temp.
-
-Signed-off-by: Ansuel Smith <ansuelsmth@gmail.com>
----
- drivers/thermal/qcom/tsens-8960.c | 8 ++++----
- 1 file changed, 4 insertions(+), 4 deletions(-)
-
---- a/drivers/thermal/qcom/tsens-8960.c
-+++ b/drivers/thermal/qcom/tsens-8960.c
-@@ -45,11 +45,11 @@
- #define S9_STATUS_OFF         0x3674
- #define S10_STATUS_OFF                0x3678
--/* Original slope - 200 to compensate mC to C inaccuracy */
-+/* Original slope - 350 to compensate mC to C inaccuracy */
- static u32 tsens_msm8960_slope[] = {
--                      976, 976, 954, 976,
--                      911, 932, 932, 999,
--                      932, 999, 932
-+                      826, 826, 804, 826,
-+                      761, 782, 782, 849,
-+                      782, 849, 782
-                       };
- static int suspend_8960(struct tsens_priv *priv)