1 #include <dt-bindings/gpio/gpio.h>
6 compatible = "lantiq,xway", "lantiq,danube";
13 stdout-path = "serial0:115200n8";
21 compatible = "mips,mips24Kc";
27 compatible = "syscon-reboot";
37 compatible = "lantiq,biu", "simple-bus";
38 reg = <0x1f800000 0x800000>;
39 ranges = <0x0 0x1f800000 0x7fffff>;
42 #interrupt-cells = <1>;
44 compatible = "lantiq,icu";
53 compatible = "lantiq,wdt";
61 compatible = "lantiq,sram", "simple-bus";
62 reg = <0x1f000000 0x800000>;
63 ranges = <0x0 0x1f000000 0x7fffff>;
66 #interrupt-cells = <1>;
68 compatible = "lantiq,eiu-xway";
69 reg = <0x101000 0x1000>;
70 interrupt-parent = <&icu0>;
71 lantiq,eiu-irqs = <166 135 66>;
75 compatible = "lantiq,pmu-xway";
76 reg = <0x102000 0x1000>;
80 compatible = "lantiq,cgu-xway";
81 reg = <0x103000 0x1000>;
87 compatible = "lantiq,vmmc-xway";
88 reg = <0x107000 0x400>;
89 interrupt-parent = <&icu0>;
90 interrupts = <150 151 152 153 154 155>;
96 compatible = "lantiq,danube-rcu", "simple-mfd", "syscon";
97 reg = <0x203000 0x1000>;
98 ranges = <0x0 0x203000 0x100>;
101 reset: reset-controller@10 {
102 compatible = "lantiq,danube-reset";
103 reg = <0x10 4>, <0x14 4>;
108 usb_phy: usb2-phy@18 {
109 compatible = "lantiq,danube-usb2-phy";
113 resets = <&reset 4 4>;
114 reset-names = "ctrl";
121 #address-cells = <1>;
123 compatible = "lantiq,fpi", "simple-bus";
124 ranges = <0x0 0x10000000 0xeefffff>;
125 reg = <0x10000000 0xef00000>;
127 localbus: localbus@0 {
128 #address-cells = <2>;
130 ranges = <0 0 0x0 0x3ffffff /* addrsel0 */
131 1 0 0x4000000 0x4000010>; /* addsel1 */
132 compatible = "lantiq,localbus", "simple-bus";
136 compatible = "lantiq,gptu-xway";
137 reg = <0xe100a00 0x100>;
138 interrupt-parent = <&icu0>;
139 interrupts = <126 127 128 129 130 131>;
144 compatible = "lantiq,gpio-stp-xway";
146 reg = <0xe100bb0 0x40>;
147 lantiq,shadow = <0xfff>;
148 lantiq,groups = <0x3>;
152 asc0: serial@e100400 {
153 compatible = "lantiq,asc";
154 reg = <0xe100400 0x400>;
155 interrupt-parent = <&icu0>;
156 interrupts = <104 105 106>;
160 gpio: pinmux@e100b10 {
161 compatible = "lantiq,danube-pinctrl";
164 reg = <0xe100b10 0xa0>;
167 asc1: serial@e100c00 {
168 compatible = "lantiq,asc";
169 reg = <0xe100c00 0x400>;
170 interrupt-parent = <&icu0>;
171 interrupts = <112 113 114>;
175 compatible = "lantiq,danube-usb";
176 reg = <0xe101000 0x1000
178 interrupt-parent = <&icu0>;
182 phy-names = "usb2-phy";
187 compatible = "lantiq,deu-danube";
188 reg = <0xe103100 0xf00>;
192 compatible = "lantiq,dma-xway";
193 reg = <0xe104100 0x800>;
197 compatible = "lantiq,ebu-xway";
198 reg = <0xe105300 0x100>;
202 compatible = "lantiq,mei-xway";
203 reg = <0xe116000 0x400>;
204 interrupt-parent = <&icu0>;
209 compatible = "lantiq,etop-xway";
210 reg = <0xe180000 0x40000>;
211 interrupt-parent = <&icu0>;
212 interrupts = <73 78>;
213 mac-address = [ 00 11 22 33 44 55 ];
217 compatible = "lantiq,ppe-danube";
218 reg = <0xe234000 0x40000>;
219 interrupt-parent = <&icu0>;
226 #address-cells = <3>;
228 #interrupt-cells = <1>;
229 compatible = "lantiq,pci-xway";
230 bus-range = <0x0 0x0>;
231 ranges = <0x2000000 0 0x8000000 0x8000000 0 0x2000000 /* pci memory */
232 0x1000000 0 0x00000000 0xae00000 0 0x200000>; /* io space */
233 reg = <0x7000000 0x8000 /* config space */
234 0xe105400 0x400>; /* pci bridge */
235 lantiq,bus-clock = <33333333>;
236 interrupt-map-mask = <0xf800 0x0 0x0 0x7>;
237 interrupt-map = <0x7000 0 0 1 &icu0 30 1>; /* slot 14, irq 30 */
238 req-mask = <0x1>; /* GNT1 */
243 compatible = "lantiq,adsl-danube";