#!/bin/sh /etc/rc.common START=98 boot() { . /lib/functions.sh #configuring (lm85/lm63) onboard temp/fan controller to run the fan on its own #for more information, please read https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface case $(board_name) in zyxel,nsa310b) path_to_hwmon='/sys/devices/platform/ocp@f1000000/f1011000.i2c/i2c-0/0-002e/hwmon/hwmon0' echo 2 > "$path_to_hwmon/pwm1_enable" # fan is on pwm1 echo 1 > "$path_to_hwmon/pwm1_auto_channels" # temp1 is the only one that changes echo 23000 > "$path_to_hwmon/temp1_auto_temp_min" echo 43000 > "$path_to_hwmon/temp1_auto_temp_max" # next step is 49600 millicelsius, or 50 celsius, 43 celsius is better ;; iom,ix2-200) path_to_hwmon='/sys/class/hwmon/hwmon0' echo 2 > "$path_to_hwmon/pwm1_enable" # fan is on pwm1 ;; esac }