summaryrefslogtreecommitdiffstats
path: root/modules/admin-full/luasrc/view/admin_system/flashops.htm
blob: 0ba22a5e01c43c341ad052f9ec895d6ccb1e99c3 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
<%#
LuCI - Lua Configuration Interface
Copyright 2008 Steven Barth <steven@midlink.org>
Copyright 2008 Jo-Philipp Wich <xm@leipzig.freifunk.net>

Licensed under the Apache License, Version 2.0 (the "License");
you may not use this file except in compliance with the License.
You may obtain a copy of the License at

	http://www.apache.org/licenses/LICENSE-2.0

$Id$

-%>

<%+header%>

<h2><a id="content" name="content"><%:Flash operations%></a></h2>

<ul class="cbi-tabmenu">
	<li class="cbi-tab"><a href="#"><%:Actions%></a></li>
	<li class="cbi-tab-disabled"><a href="<%=REQUEST_URI%>/backupfiles"><%:Configuration%></a></li>
</ul>

<fieldset class="cbi-section">

	<fieldset class="cbi-section">
		<legend><%:Backup / Restore%></legend>
		<form method="post" action="<%=REQUEST_URI%>" enctype="multipart/form-data">
			<div class="cbi-section-descr"><%:Click "Generate archive" to download a tar archive of the current configuration files. To reset the firmware to its initial state, click "Perform reset" (only possible with squashfs images).%></div>
			<div class="cbi-section-node">
				<div class="cbi-value<% if not reset_avail then %> cbi-value-last<% end %>">
					<label class="cbi-value-title" for="image"><%:Download backup%>:</label>
					<div class="cbi-value-field">
						<input class="cbi-button cbi-button-apply" type="submit" name="backup" value="<%:Generate archive%>" />
					</div>
				</div>
				<% if reset_avail then %>
				<div class="cbi-value cbi-value-last">
					<label class="cbi-value-title"><%:Reset to defaults%>:</label>
					<div class="cbi-value-field">
						<input onclick="return confirm('<%:Really reset all changes?%>')" class="cbi-button cbi-button-reset" type="submit" name="reset" value="<%:Perform reset%>" />
					</div>
				</div>
				<% end %>
			</div>
			<br />
			<div class="cbi-section-descr"><%:To restore configuration files, you can upload a previously generated backup archive here.%></div>
			<div class="cbi-section-node">
				<div class="cbi-value cbi-value-last">
					<label class="cbi-value-title" for="archive"><%:Restore backup%>:</label>
					<div class="cbi-value-field">
						<input type="file" name="archive" id="archive" />
						<input type="submit" class="cbi-button cbi-input-apply" name="restore" value="<%:Upload archive...%>" />
					</div>
				</div>
			</div>
		</form>
	</fieldset>

	<br />

	<fieldset class="cbi-section">
		<legend><%:Flash new firmware image%></legend>
		<% if upgrade_avail then %>
			<form method="post" action="<%=REQUEST_URI%>" enctype="multipart/form-data">
				<div class="cbi-section-descr"><%:Upload a sysupgrade-compatible image here to replace the running firmware. Check "Keep settings" to retain the current configuration (requires an OpenWrt compatible firmware image).%></div>
				<div class="cbi-section-node">
					<div class="cbi-value">
						<label class="cbi-value-title" for="keep"><%:Keep settings%>:</label>
						<div class="cbi-value-field">
							<input type="checkbox" name="keep" id="keep" checked="checked" />
						</div>
					</div>
					<div class="cbi-value cbi-value-last<% if image_invalid then %> cbi-value-error<% end %>">
						<label class="cbi-value-title" for="image"><%:Image%>:</label>
						<div class="cbi-value-field">
							<input type="file" name="image" id="image" />
							<input type="submit" class="cbi-button cbi-input-apply" value="<%:Flash image...%>" />
						</div>
					</div>
				</div>
				<% if image_invalid then %>
					<div class="cbi-section-error"><%:The uploaded image file does not contain a supported format. Make sure that you choose the generic image format for your platform. %></div>
				<% end %>
			</form>
		<% else %>
			<div class="cbi-section-descr"><%:Sorry, there is no sysupgrade support present, a new firmware image must be flashed manually. Please refer to the OpenWrt wiki for device specific install instructions.%></div>
		<% end %>
	</fieldset>

</fieldset>

<%+footer%>